MTS-122 Meter Test System
The MTS-122 is a high-precision, multifunctional three-phase Meter Test System designed for calibration and testing of a wide variety of equipment, including:
Analog and digital meters
RTUs (Remote Terminal Units)
Electrical transducers
Energy meters
With accuracy classes 0.05 and 0.1, modular structure, and a broad output range (AC & DC, up to 36A and 1000V/1100V), the MTS-122 is ideal for research institutions, calibration laboratories, utilities, and meter manufacturers.
Key Features
-
Dual output capability: AC & DC voltage and current sources
-
Accuracy class 0.05% or 0.1%
-
Wide measurement scope:
-
AC Voltage: 300mV–1000V (single phase), 57.7V–660V (three phase)
-
AC Current: 2mA–30A (single phase), 0.2A–30A (three phase)
-
DC Voltage: 75mV–750V
-
DC Current: 100µA–30A
-
-
Full harmonic generation and analysis: 2nd–63rd harmonics
-
Rugged modular design with 8” TFT touch-screen interface
-
Self-protection and diagnostics: overload, short-circuit, open-circuit, amplifier failure detection
-
Interfaces: RS-232, RS-485, Ethernet, USB, WiFi, I/O
-
Remote firmware update and diagnosis
-
Automatic or user-defined calibration system supported
Technical Specifications
AC Large Voltage Output
-
Range: L1: 30V, 100V, 300V, 660V, 1000V; L2 & L3: 30V, 100V, 300V, 660V
-
Adjusting Range: 0–120% RG (1000V: 0–100% RG)
-
Resolution: 0.01%, 0.1%, 1%, 10% RG
-
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
-
Distortion: ≤0.2%
-
Max Load: 20VA/phase
AC Small Voltage Output
-
Range (L1): 75mV, 300mV, 750mV, 3V, 7.5V
-
Adjusting Range: 0–120% RG
-
Stability: 0.02%/2min
-
Distortion: ≤0.2%
-
Load: ≥25mA
-
Accuracy: 0.1% RG
AC Current Output
-
Range: L1 (2mA–30A), L2/L3 (200mA–30A)
-
Adjusting Range: 0–120% RG
-
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
-
Distortion: ≤0.2%
-
Load: 20VA (30A gear), ≥15V (50mA and below)
-
Accuracy: 0.05% RG (≥200mA), 0.1% RG (≤50mA)
DC Voltage Output
-
Range: 100mV–1000V
-
Adjusting Range: 0–120% RG (1000V: 0–100%)
-
Stability: 0.01%/2min (Class 0.05)
-
Ripple: ≤1%
-
Load: ≥50mA
DC Current Output
-
Range: 100µA–30A
-
Adjusting Range: 0–120% RG
-
Stability: 0.01%/2min (Class 0.05)
-
Ripple: ≤1%
-
Load: 25VA at 25A; ≥30V at ≤1A
Phase Output
-
Range: 0°–360°
-
Resolution: 0.01°
-
Accuracy: 0.05°
Frequency Output
-
Range: 40Hz–70Hz
-
Resolution: 0.001Hz
-
Accuracy: ±0.002Hz
Harmonics
-
Order: 2nd–63rd
-
Amplitude: 0–40%
-
Angle: 0°–359.99°
-
Error: ≤±0.1% (2nd–31st), ≤±0.2% (32nd–63rd)
Energy Error Measurement
-
Active Energy:
-
±0.05% RD (V: 15–660V, I: 0.05–36A, PF ≥0.5)
-
±0.1% RD (V: 15–660V, I: 0.02–0.05A, PF=1)
-
-
Reactive Energy:
-
±0.1% RD (V: 15–660V, I: 0.05–36A, PF ≥0.5)
-
±0.2% RD (V: 15–660V, I: 0.02–0.05A, PF=1)
-
Other Parameters
-
Power Supply: 90–265VAC/DC
-
Frequency: 50–60Hz
-
Consumption: 50–1000VA
-
Operating Temp: 20–30°C; Humidity ≤85% RH
-
Storage Temp: -20–50°C
-
Dimensions: 600 × 440 × 176 mm
-
Weight: 30kg
Unique Features
-
Integration of high-accuracy reference meter + power source
-
Capable of testing: meters, RTUs, transducers, and multifunction devices
-
Generates and analyzes harmonics (2nd–63rd)
-
Relay and pulse outputs for response time tests
-
Full self-diagnosis for amplifier and communication module failures
-
Supports testing of Class 0.2 meters and below using Class 0.05 system