Integrated Transformer Testing Solution
The Integrated Transformer Testing Solution from KVTEK is a comprehensive modular system designed to test all critical electrical parameters of power and distribution transformers. It provides accurate measurement of no-load loss, load loss, impedance, induced voltage, heat run, and partial discharge — all within a unified test bay.
Engineered for high-performance laboratories and transformer manufacturers, the system integrates a static frequency converter, multi-tap step-up transformer, capacitor bank, TLM loss measuring system, and optional PD test components, ensuring maximum flexibility, precision, and automation in compliance with IEC/ANSI standards.
Function
-
Complete high-voltage testing platform for power and distribution transformers
-
Performs loss, impedance, dielectric strength, partial discharge, and thermal tests in one unified system
-
Combines multiple test functions with automated measurement and reporting
Application
-
Power transformer manufacturers
-
Utilities (Transmission & Distribution)
-
R&D and HV test laboratories
-
Transformer acceptance and type testing
Key Equipment
-
Static frequency converter (SFC)
-
3-phase multi-tap step-up transformer
-
MVAr-rated capacitor bank with manual/auto isolator switching
-
Transformer Loss Measuring System (TLM)
-
Optional multi-channel PD detector with HV filter
Equipment Specification
SFC Specifications
-
Output voltage: 350–580 VAC
-
Output frequency: 40–200 Hz
-
Power rating: 20 kVA to 10 MVA
-
Input voltage: 415–690 VAC ±5%
-
Total harmonic distortion: <3%
-
Voltage & frequency resolution: 0.1 V / 0.1 Hz
-
Protection class: IP21
-
Remote controlled via industrial PC (Profibus)
-
Efficiency: 96–98%
-
Optional harmonic current injection
Step-Up Transformer
-
3-phase with high-frequency screens (Core–LV and LV–HV)
-
Operates from 40–400 Hz
-
Multiple secondary off-load taps
-
Low impedance and low flux density design
Capacitor Bank
-
Star/delta connected
-
Manual or automated MVAr stage selection
-
Protected against unbalanced current
-
Flexible MVAr rating configuration per application
Transformer Loss Measuring System (TLM)
-
High accuracy: ±0.5% of indicated power
-
Measures no-load loss, load loss, and impedance
-
Software-aided operation with automatic report generation
-
Eliminates manual range switching
-
IEC/ANSI compliant (40 Hz to 400 Hz operation)
Environmental Conditions
-
Ambient temperature: 5–40°C
-
Relative humidity: <95% (non-condensing)
Accessories
-
Wall bushings
-
Water chiller plant (for water-cooled SFCs)
-
Corona spinning system
-
Interconnecting busbars and cables
-
Intertwined copper ropes for test hookup
-
Integrated earthing network