DGA.1000 – Dissolved Gas Analyser (Chromatograph)

The DGA.1000 Transformer Oil Gas Chromatograph is designed for determining the content of dissolved gases in insulating oil. By a single injection, it can analyze key gases such as CO₂, CH₄, C₂H₂, C₂H₄, and C₂H₆, with a minimum acetylene detection concentration of 0.1 ppm.

Equipped with a large LCD interface and user-friendly menus, it enables accurate, efficient, and repeatable dissolved gas analysis. The system features a two-column parallel shunt system, thermal conductivity detector, dual hydrogen flame detector, and a nickel catalyst reforming furnace for reliable operation.

A PCBs model for ASTM D4059 testing is also available upon request.

Compliance Standards:

  • GB/T 17623-1998 – Gas-chromatographic determination of dissolved gas content in insulating oils

  • GB/T 7252-2001 – Guidelines for Analysis and Judgment of Dissolved Gases in Transformer Oils

  • DL/T 722-2000 – Guidelines for Analysis and Judgment of Dissolved Gases in Transformer Oils

Key Features

  • Cost-effective, multi-functional, and accurate gas chromatography system.

  • Equipped with TCD + dual FID detectors, with optional ECD, FPD, and NPD detectors.

  • Supports constant temperature and programmed temperature operation.

  • Micro-computer and integrated circuit control with data storage & transfer functions.

  • High-precision temperature control with rapid heating/cooling.

  • Pneumatic process is flexible, reliable, and expandable.

  • Up to four detectors can be installed simultaneously.

  • Multiple injection system options: packed column, glass-lined quick injection, capillary column split/spitless with diaphragm cleaning.

  • Over-temperature protection with automatic shutdown and alarm.

  • Signal outputs compatible with chromatographic data processors and workstations.

  • Carrier gas circuit protection prevents column and detector damage during TCD operation.

  • Automatic ignition function with workstation control capability.

Technical Specifications

  • Temperature Control Range: Room temperature + 4°C ~ 450°C

  • Temperature Accuracy: ±0.01°C

  • Display Accuracy: 0.1°C

  • Heating Rate: 0 – 40°C/min, adjustable in 0.1°C increments (16-step programming)

  • Programmed Temp Repeatability: ≤1%

TCD Detector

  • Sensitivity: S ≥ 3500 mV·ml/mg (benzene)

  • Baseline drift: ≤25 µV / 30 min

  • Baseline noise: ≤10 µV

  • Linear range: ≥10⁴

FID Detector

  • Detection limit: ≤3 × 10⁻¹² g/s (positive hexadecane)

  • Baseline drift: ≤1 × 10⁻¹³ A / 30 min

  • Baseline noise: ≤5 × 10⁻¹⁴ A

  • Linear range: ≥10⁴

Automation & Protection

  • 6 independent temperature-controlled channels (vaporization & capillary chambers).

  • 8-stage programmable temperature rise function.

  • Over-temperature protection with automatic shutdown.

  • Self-diagnostic function with clear fault location and alarms.

Standard Accessories

  • Main Host Unit (with nickel catalyst conversion furnace, packed column vaporization chamber, TCD, and dual FID detectors)

  • 2 × Chromatography Columns for transformer oil

  • 1 × Automatic Degassing Oscillator

  • 1 × Transformer Oil Dedicated Chromatography Workstation

  • 1 × Air Generator

  • 1 × Hydrogen Generator

  • 1 × High Purity Nitrogen Cylinder / Bottle

  • 1 × Standard Gas Bottle

  • 1 × PC and Printer