top of page

Cropico MTS Series

The Cropico MTS Series milliohmmeter test standards are designed for the simple and accurate calibration of low resistance ohmmeters and Kelvin/Thomson bridges. Resistance values are four-terminal, switch-selected, and provision is made for both positive and negative full-scale values. A four-terminal zero value may also be selected, allowing straightforward zero and full-scale calibration.

The internal standards are manufactured from premium quality resistance wire with low temperature and load coefficients, ensuring long-term stability and accuracy. All units are housed in a rugged bench-portable aluminium case with tilt handle and are supplied with a calibration certificate traceable to international standards.

Model Options

Function

• Calibration of low resistance ohmmeters and bridges
• Four-terminal resistance values for precision
• Switch-selected resistance ranges with ± full-scale values
• Zero value option for simple calibration
• Rugged portable design for bench use
• Supplied with calibration certificate

Technical Specifications

MTS1A – Part Number: 930240

Resistance values: 1 mΩ to 100 kΩ (11 steps)

  • Uncertainty of adjustment: ±0.01% to ±0.05% (depending on value)

  • Power max: 0.1–0.625 W

  • Current max: 1 mA to 10 A

  • Temperature coefficient: <10 ppm/°C

Resistance Value Uncertainty at 20°C Power Max (W) Current Max (A) Temp. Coeff.
100 kΩ ±0.01% 0.1 1 mA <10 ppm/°C
10 kΩ ±0.01% 0.1 3 mA <10 ppm/°C
1 kΩ ±0.01% 0.6 25 mA <10 ppm/°C
100 Ω ±0.01% 0.6 75 mA <10 ppm/°C
10 Ω ±0.01% 0.43 150 mA <10 ppm/°C
1 Ω ±0.01% 0.45 212 mA <10 ppm/°C
0.1 Ω ±0.01% 0.475 500 mA <10 ppm/°C
0.01 Ω ±0.01% 0.65 750 mA <10 ppm/°C
0.001 Ω ±0.05% 0.25 5 A <10 ppm/°C
10 mΩ ±0.05% 0.25 5 A <10 ppm/°C
1 mΩ ±0.05% 0.1 10 A <10 ppm/°C

MTS2 – Part Number: 930241

Resistance values: 400 μΩ to 400 kΩ (10 steps)

  • Uncertainty of adjustment: ±0.01% to ±0.1%

  • Power max: 0.04–0.4 W

  • Current max: 1.5 mA to 10 A

  • Temperature coefficient: <10 ppm/°C

Resistance Value Uncertainty at 20°C Power Max (W) Current Max (A) Temp. Coeff.
400 kΩ ±0.01% 0.1 0.45 mA <10 ppm/°C
40 kΩ ±0.01% 0.1 1.5 mA <10 ppm/°C
4 kΩ ±0.01% 0.1 5 mA <10 ppm/°C
400 Ω ±0.01% 0.1 15 mA <10 ppm/°C
40 Ω ±0.01% 0.1 50 mA <10 ppm/°C
4 Ω ±0.01% 0.1 150 mA <10 ppm/°C
400 mΩ ±0.01% 0.1 500 mA <10 ppm/°C
40 mΩ ±0.01% 0.1 1.5 A <10 ppm/°C
4 mΩ ±0.1% 0.4 10 A <10 ppm/°C
400 μΩ ±0.1% 0.04 10 A <10 ppm/°C

MTS3 – Part Number: 930242

Resistance values: 5 mΩ to 5 Ω (4 steps)

  • Designed for pulsed current calibration (e.g. DO7010)

  • Not intended for continuous current measurement

  • Temperature coefficient: <10 ppm/°C

Resistance Value Uncertainty at 20°C Current Max (2 s) Temp. Coeff.
5 Ω ±0.05% 1 A <10 ppm/°C
500 mΩ ±0.05% 10 A <10 ppm/°C
50 mΩ ±0.05% 10 A <10 ppm/°C
5 mΩ ±0.1% 10 A <10 ppm/°C

Model Options and Applications

  • MTS1A: 11 resistance values from 1 mΩ to 100 kΩ. General calibration of low resistance ohmmeters and bridges.

  • MTS2: 10 resistance values from 400 μΩ to 400 kΩ. Ideal for digital instruments with long scale lengths (4000–6000 count).

  • MTS3: 4 resistance values from 5 mΩ to 5 Ω. Suited for calibration of pulsed current instruments such as the Cropico DO7010.