PL-9009 SF - PLC Based Automatic Safety Analyzer
First file
Second file
Third file
About the D-9009 SF
The PC Based Automatic Safety Analyzer is ideally suited for fast-paced production lines delivering high volumes of finished household appliances. Widely adopted by leading manufacturers such as Tecumseh, Havells, Hitachi, IFB, LG, Voltas, Videocon, Yash Fans, this analyzer ensures reliable, accurate, and automated safety testing.
Key Features
-
Infinite model storage capability
-
Job work management for motor data reference
-
17-inch DELL monitor with ADVANTECH industrial PC
-
LABVIEW-based software to test, store & print reports
-
Permission-based login system
-
Software-defined limits for test parameters
-
Remote online calibration & support
-
Barcode/QR code reading capability
Applications
-
Motors of table fans & exhaust fans
-
Motors of coolers, blowers & pumps
-
Household appliances in production & rewound motor testing
Benefits
-
Large 17-inch colour-coded display screen
-
Audio/visual alarms for faulty units
-
Direct USB printer connectivity for reports
-
MS Excel report generation with pie & bar charts
Accessories
-
Start/Stop remote switch
-
Dust-free enclosure housing
-
In-house UPS for PC & monitor
PC Specifications
-
Monitor: 17-inch DELL
-
PC: ADVANTECH Industrial PC
-
OS/Software: Windows 10, MS Office 2015, Antivirus
-
Design: Dust-proof, water-resistant, 0–60 °C
-
Connectivity: 6 USB ports, VGA, LAN
-
Input Devices: Wireless keyboard & mouse
-
DAQ & Sensors: National Instruments DAQ cards, temperature sensor
Software Indicators & Controls
-
Adjustable Volts/Div and TimeBase
-
Colour-coded waveform display
-
Surge test peak voltage indicator
-
Graphical & numerical %error display
-
Target voltage indicator (based on appliance rating)
-
Test result lamp indicator
-
Save, recall & print waveforms & reports
Test Sequence & Specifications
I) Ground Test
-
Voltage: 10 V AC
-
Current: 25 A
-
Time: 0–10 sec
-
Limit: 0–10 A
II) I.R (Megohm) Test
-
Voltage: 500 V DC
-
Time: 0–10 sec
-
Limit: 0–200 MΩ
III) H.V Flash Test
-
Formula: HV Flash = (2×E + 1000), where E = operating voltage
-
Voltage: 0–2.5 kV AC (Adjustable)
-
Time: 0–10 sec
-
Leakage Current Limit: 0.1–10 mA
IV) Low Voltage (Startability) Test
-
Voltage: 0–270 V (Adjustable)
-
Wattage: 0–2000 W
-
Current: 0–8 A
-
Power Factor: 0.000–1.000
-
Time: 0–30 sec
V) Full Voltage Run Test
-
Voltage: 0–270 V (Adjustable)
-
Wattage: 0–2000 W
-
Current: 0–8 A
-
Power Factor: 0.000–1.000
-
Time: 0–30 sec
VI) Leakage Current Test
-
Voltage: 255 V AC
-
Time: 0–10 sec
-
Leakage Current Limit: 0.1–10 mA