MASTECH MS2308 Advanced Earth Resistance Tester
The MS2308 is a versatile, high-precision earth ground resistance tester designed for multi-method resistance testing in residential, industrial, and infrastructure settings. Supporting 2-pole, 3-pole, 4-pole, and clamp methods, it offers a comprehensive solution for ground system verification, including soil resistivity, resistance compensation, and interference voltage detection.
With 9999-count dual digital/analog display, automatic ranging, and multiple test frequencies, the MS2308 delivers accurate results even in the presence of electrical noise. Additional features such as data storage, USB connectivity, and limit alarms make this instrument a reliable tool for professional field applications.
Key Features
-
Dual display: Digital (9999 counts) & Analog bargraph
-
Automatic power-off
-
Clock function
-
AVG (average) function
-
Compensation resistance (RK) testing
-
Limit-value alarm indicator
-
Battery capacity indicator
-
Backlit LCD display
-
User-defined spacing for resistivity testing
-
Data storage: 100 test records
-
USB interface for data transfer
Technical Specifications
Measurement Modes & Parameters
3-Pole / 4-Pole Earthing Resistance (AC)
-
Test Voltage: AC 20 V / 48 V
-
Test Frequency: 94 Hz / 128 Hz
-
Range: 0.02 Ω – 300 kΩ
-
Resolution: 0.001 Ω
-
Accuracy: ±(5% + 10)
Clamp Mode (No Auxiliary Rods)
-
Test Voltage: AC 20 V / 48 V
-
Test Frequency: 94 Hz / 128 Hz
-
Range: 0.02 Ω – 150 Ω
-
Resolution: 0.001 Ω
-
Accuracy: ±(10% + 10)
2-Pole Resistance (AC)
-
Range: 0.02 Ω – 300 kΩ
-
Resolution: 0.001 Ω
-
Accuracy: ±(5% + 10)
2/4 Pole Resistance (DC)
-
Interfering Voltage Tolerance: 1–50 V (AC/DC)
-
Interfering Frequency: 16 Hz – 400 Hz
-
Range: 0.02 Ω – 3 kΩ
-
Resolution: 0.001 Ω
-
Accuracy: ±(5% + 10)
Soil Resistivity (ρ)
-
Test Voltage: AC 20 V / 48 V
-
Test Frequencies: 94 Hz / 105 Hz / 111 Hz / 128 Hz / AFC (Auto Frequency Control)
-
Range: 0.02 – 1000 kΩ·m
-
Resolution: 0.001 Ω
-
Accuracy: ±(5% + 10)
Compensation Resistance (RK)
-
Test Voltage: AC 20 V / 48 V
-
Frequencies: 94 Hz / 105 Hz / 111 Hz / 128 Hz / AFC
-
Range: Up to 30 Ω
-
Resolution: 0.001 Ω
-
Accuracy: ±(3% + 10)
Interference Measurement Capability
| Parameter | Range | Resolution | Accuracy |
|---|---|---|---|
| Interfering Voltage | 1 – 50 V AC/DC | 0.1 V | ±(5% + 5) |
| Interfering Current | 20 mA – 2 A | 1 mA | ±(5% + 5) |
| Interfering Frequency | 16 Hz – 400 Hz | 1 Hz | ±(1% + 10) |
Additional Information
| Function | Specification |
|---|---|
| Display Count | 9999 |
| DC Voltage Range | 0 – 20 V |
| AC Voltage Range | 0 – 48 V |
| 3-Pole & 4-Pole Resistance | Yes |
| Resistance Range | Up to 300 kΩ |
| Soil Resistivity | Yes |
| Overrange Indication | Yes |
| Low Battery Indicator | Yes |
| Backlight | Yes |
| Data Logging | 100 groups |
| Interface | USB |
| Data Hold | No |
| Resistivity Test Point Setting | Yes |
.png)