PC Based Automatic Safety Analyzer – D-9009 SF
About the D-9009 SF
The D-9009 SF Automatic Safety Analyzer is designed for high-volume production lines of household appliances. Widely adopted by leading manufacturers such as Tecumseh, Havells, Hitachi, IFB, LG, Voltas, Videocon, and Yash Fans, this system ensures reliable, fast, and accurate safety testing of motors and appliances.
Key Features
-
Infinite model storage capability
-
Job work management area for motor data reference
-
17-inch DELL monitor with ADVANTECH industrial PC
-
LABVIEW software for test, storage, and reporting
-
Permission-based login system
-
Software-defined test parameter limits
-
Remote calibration and support via online access
-
Barcode/QR code reading facility
Applications
-
Motors of table fans and exhaust fans
-
Cooler motors
-
Blower motors
-
Pump motors
Benefits
-
17-inch colour-coded display screen
-
Audio/visual alarms for faulty appliances
-
USB printer connectivity for direct printouts
-
MS Excel report generation with charts
Accessories
-
Start/Stop remote switch
-
Dust-free enclosure housing
-
Inbuilt UPS for PC and monitor
PC Specifications
-
Monitor: 17-inch DELL
-
PC: ADVANTECH Industrial PC
-
OS/Software: Windows 10, MS Office 2015, Antivirus
-
Design: Dust-proof, water-resistant, 0–60°C
-
Connectivity: 6 USB ports, VGA port, LAN port
-
Input Devices: Wireless keyboard & mouse
-
DAQ & Sensors: National Instruments DAQ cards and temperature sensor
Software Indicators & Controls
-
Adjustable Volts/Div and TimeBase
-
Colour-coded waveform display
-
Surge test peak voltage indicator
-
Graphical and numerical % error display
-
Target voltage indicator based on motor rating
-
Test result lamp indicator
-
Save, recall, and print waveforms & reports
Test Sequence & Specifications
I) Ground Test
-
Voltage: 10 V AC
-
Current: 25 A
-
Time: 0–10 sec
-
Limit: 0–10 A
II) I.R (Megohm) Test
-
Voltage: 500 V DC
-
Time: 0–10 sec
-
Limit: 0–200 MΩ
III) H.V Flash Test
-
Formula: H.V Flash = (2 × E + 1000)
-
Voltage: 0–2.5 kV AC (Adjustable)
-
Time: 0–10 sec
-
Leakage Current Limit: 0.1–10 mA
IV) Low Voltage (Startability) Test
-
Voltage: 0–270 V (Adjustable)
-
Wattage Limit: 0–2000 W
-
Current Limit: 0–8 A
-
Power Factor: 0.000–1.000
-
Time: 0–30 sec
V) Full Voltage Run Test
-
Voltage: 0–270 V (Adjustable)
-
Wattage Limit: 0–2000 W
-
Current Limit: 0–8 A
-
Power Factor: 0.000–1.000
-
Time: 0–30 sec
VI) Leakage Current Test
-
Voltage: 255 V AC
-
Time: 0–10 sec
-
Leakage Current Limit: 0.1–10 mA
.png)