top of page

PC Based Online Ceiling Fan Analyzer – D-9005 CFA

About the D-9005 CFA

The D-9005 CFA is a PC Based Automatic Ceiling Fan Analyzer, designed for conveyor-based testing of ceiling fans, including BLDC fans. It automatically checks the performance and quality of each fan by applying voltage to bus bars mounted on the conveyor and executing a sequence of automated tests.

Key Features

  • Infinite model storage capability

  • Job work management area for test data reference

  • 17-inch DELL monitor with ADVANTECH industrial PC

  • LABVIEW-based software for testing, storing, and printing reports

  • Permission-based login system

  • Software-defined limits for all test parameters

  • Online calibration and support via remote access

Applications

  • Online testing of ceiling fans

  • Compatible with BLDC fans

  • Designed for integration with production conveyor lines

Benefits

  • Large 17-inch colour-coded display screen

  • Audio and visual alarms for faulty fans

  • Direct printer connectivity via USB

  • MS Excel report generation with pie and bar chart outputs

Accessories

  • Dust-free enclosure housing

  • Inbuilt UPS for PC and monitor

PC Specifications

  • Monitor: 17-inch DELL

  • PC: ADVANTECH Industrial PC

  • RAM/Storage: 4GB RAM / 500GB HDD

  • OS/Software: Windows 10, MS Office 2015, Antivirus

  • Connectivity: 6 USB ports, VGA port, LAN port

  • Input Devices: Wireless keyboard & mouse

  • DAQ Cards: National Instruments DAQ

  • Environment: Dust-proof, water-resistant, 0°C–60°C

Test Sequence & Specifications

I) H.V Flash Test (Bus Bar I)

  • Checks insulation strength at higher applied voltage.

  • Formula: H.V Flash = (2 × E + 1000), where E = operating voltage

  • Voltage: 0–2.5 kV AC (Adjustable)

  • Test Time: 0–10 sec

  • Leakage Current Limit: 0.1–10 mA

II) Low Voltage Start Test (Bus Bar II)

  • Ensures fan starts smoothly at low voltage without jamming.

  • Voltage: 0–270 V (Adjustable)

  • Wattage Limit: 0–2000 W

  • Current Limit: 0–8 A

  • Power Factor Limit: 0.000–1.000

  • Test Time: 0–10 sec

III) Full Voltage No Load Test (Bus Bar III)

  • Evaluates performance at full operating voltage (~230V).

  • Voltage: 0–270 V (Adjustable)

  • Wattage Limit: 0–2000 W

  • Current Limit: 0–8 A

  • Power Factor Limit: 0.000–1.000

  • Test Time: 0–10 sec

bottom of page