BT-120 Battery Tester
Function
-
Measures internal impedance, voltage, ripple voltage, and AC/DC current
-
Diagnoses battery health and charging issues
-
Supports industrial, automotive, and telecom applications
Standard Accessories
-
Set of cables for internal impedance (WAPRZBT120ZS)
-
Measuring clamp C-130BE (WACEGC130BE)
-
Calibration resistor (WAADARK1)
-
Set of voltage measurement cables (WAPRZBT120U)
-
Carrying case L-17 (WAFUTL17)
-
USB data adapter (WAADABTUSB1)
-
Z-34 power supply (WAZASZ34)
Technical Specifications
voltage measurement
-
DC voltage: 0–500 V
-
Resolution: from 0.001 V
-
Accuracy: ±(0.5% m.v. + 5 digits)
-
-
AC voltage: 0–500 V
-
Resolution: 0.1 V
-
Accuracy: ±(0.75% m.v. + 5 digits)
-
-
Ripple voltage: 0–5 V
-
Resolution: 0.001 V
-
Accuracy: ±(2.5% m.v. + 10 digits)
-
current measurement
-
DC current: 0–400 A
-
Resolution: from 0.001 A
-
Accuracy: ±(0.5% m.v. + 5 digits)
-
-
AC current: 0–400 A
-
Resolution: from 0.001 A
-
Accuracy: ±(0.75% m.v. + 10 digits)
-
internal impedance
-
Range: 0–300 Ω
-
Resolution: from 1 μΩ
-
Accuracy: ±(0.5% m.v. + 10 digits)
-
temperature measurement
-
Range: -10°C to +100°C
-
Resolution: 0.1°C
-
Accuracy: ±(1% m.v. + 2 digits)
-
display
-
Graphical LCD
insulation & protection
-
Insulation: Double (EN 61010-1, IEC 61557)
-
Measurement category: CAT III 500 V
-
Ingress protection: IP54
power supply
-
AC mains: 100–240 V, 50/60 Hz
-
Battery: Rechargeable Li-Ion >5.4 Ah
dimensions
-
Size: 232 × 192 × 111 mm
-
Weight: 1.4 kg
environmental conditions
-
Operating temperature: 0°C to +50°C
-
Storage temperature: -20°C to +50°C
-
Humidity: 10–85%
-
Altitude: <2000 m
compliance
-
EMC: EN 61326-1, EN 61326-2-2
-
Quality system: ISO 9001